Advance Seeds Thailand, Spa Packages For Couple Abu Dhabi, 2 Large Egg Omelette Calories, Powerpoint Presenter View One Monitor, Alex Trochut Work, Buy Jaboticaba Seeds, Fatmagul All Episodes Watch Online, Whirlpool Refrigerator Door Panel Replacement, 0620/43 O N 17 Ms, How To Put Someone On Hold Android, " /> Advance Seeds Thailand, Spa Packages For Couple Abu Dhabi, 2 Large Egg Omelette Calories, Powerpoint Presenter View One Monitor, Alex Trochut Work, Buy Jaboticaba Seeds, Fatmagul All Episodes Watch Online, Whirlpool Refrigerator Door Panel Replacement, 0620/43 O N 17 Ms, How To Put Someone On Hold Android, " />Advance Seeds Thailand, Spa Packages For Couple Abu Dhabi, 2 Large Egg Omelette Calories, Powerpoint Presenter View One Monitor, Alex Trochut Work, Buy Jaboticaba Seeds, Fatmagul All Episodes Watch Online, Whirlpool Refrigerator Door Panel Replacement, 0620/43 O N 17 Ms, How To Put Someone On Hold Android, " />

how to install wall thimble for garage heater

The interior dimension is 4 … Install the slip connector or telescoping section last. I have a forced air Reznor garage heater installed in my garage. Below are five of the most popular places for garage heaters outside garages. Our Saf-T Vent® line of products are perfect for your commercial and industrial needs. Wall-mounted, vent-free propane heaters are a low-cost way to heat your home. A ventless natural gas infrared heater can be an easy and affordable option to run and install. Most of the heaters in this article is wall/roof mounted heaters. The red devil high temp caulk is RED!!! I tried to find an online manual for that model and could not, so I'm not sure how it hooks up. Price $102.00. Could I use the thimble by butting it against the inside of the steel panel and only cut a hole big enough for the class A chimney to pass through on the outside. The heater works great but the built in thermostat is a pita! The Double wall construction provides reduced clearances to combustibles. Suppliers of direct-vent heaters provide instructions for installing the unit yourself, but even if you feel up to the chore, it's best to have a professional install the gas line. Once that temperature dips below what is set, the heater will do what it does best and start producing heat. I think the smaller version of your Big Maxx would work well for my garage. They vent right through the outside wall. I probably went overboard with it. My oldest one is 20 years old and still works fine. https://www.mrfixitdiy.com/installing-electric-garage-heater I've been toying with the idea of doing this as well. Sealed combustion chamber, very quiet, no problems, easy install. I am installing a Hotdawg 45k BTU into my attached garage in Colorado (Denver metro area), I plan to use 3" B Vent parts using an adjustable wall Thimble thru a 2x6 wood frame wall … We HATE spam. It has a variable heat setting meaning that the heat can be tweaked up and down as per your comfort level rather than to fixed levels. This thimble is for walls 4 1/4" to 8 1/2" thick (extensions are available for thicker walls). I think it'll go back and I'll just buy B for the whole thing and the right lenght. It warms up from 35 to 55 in about 15 minutes. Choose the properly-sized gas heater for your garage. Safety Precautions when Using a Garage Heater. ANSI Category I, II, II, and IV appliances: Boilers, Water Heaters and Furnaces. In this case, you should install it on a steady part on the wall or on the roof to make sure it will not fall down, as it may cause a person or material damages. The wall thimble fell short of making a complete seal tfor the pipe to go thru. If you’re hard-wiring your heater, you’ll need to call an electrician, because you’ll have to install a new circuit breaker and new cables. Installing a garage heater in your workshop means you don't have to give up your hobbies and projects when it gets cold. Choose the properly-sized gas heater for your garage. Using an insulated or double wall chimney pipe is best. Keep your garage space warm this winter with an electric garage heater. There is a mesh exit vent mounted and sealed to the exterior wall. Grainger's got your back. These include your budget, your access to gas and electricity, venting, what type and how much heat you need. Garage heaters can be used as primary heat sources, or supplemental heat sources. A window-mounted unit is a great choice if you live in a sunny area—and especially if your garage faces due south, where it … As you can see in the video, the interior and exterior wall thimbles fit inside one another. A single-wall pipe will require 18-inch clearance to the ceiling, while double wall pipe needs an 8-inch clearance to the ceiling. Use the diagram included with your heater for the electrical connections. I need a bigger garage! Most durable, longest lasting, and lowest maintenance vent system available for Modine Hot Dawg heaters. You can see the ugly red. Always err on the side of caution and see a professional if you aren’t sure what you’re doing with electricity or gas. She loves researching the marketplace to find the right products for her household. Having a heated garage makes it an accessible and useful room no matter what your climate is. Mechanical inspector is coming today. If you’re using an infrared heater in your garage, it won’t warm the air faster than a regular heater. Built a new house last summer but didn't have them run the wiring or anything for me...kicking myself. This gives the wall thermostat the final say on whether the heater is turned on or off. Then, connect it to the wall thimble. Bigger than a portable space heater, a wall-mounted electric heater is among the best ways to heat your garage space in winter. Even electric heaters, which lack the controlled but active flame of propane/gas burning heaters, can start fires and have other adverse effects if used improperly. The 4" Wall Thimble is for use with 4" venting, through-the-wall installations. I have been waffling on buying one of these for a couple of years now. The real advantage to infrared heaters is the energy-saving costs. The 4" Wall Thimble is for use with 4" venting, through-the-wall installations. Step 4 - Install the Stove Pipe. Fahrenheat makes a 7500 watt model also, but I would have had to run new wiring for that one. This has a power exhaust. A natural gas garage heater is one of the most efficient models that you can buy to keep your garage comfortably warm for years to come. Heatfab is the leading manufacturer of high quality venting systems for Special Gas Vent applications, specified by OEMs for over 20 years. 14 gauge wire, I decided to wire a plug on the machine itself so I could be more versatile with my outlet location. Do I have to use b-vent or can I use signal wall and a thimble through the drywall board and vinyl siding. But I've put in 2 and didn't bother with that. Jennifer is a mother of 2 and has always been a careful shopper, determined to make the best buying decisions for her family. Learn more about us. There really isn't any legal way around it. Once your heater is securely fastened in place, cut a hole in the roof for the vent. The vent sticks above the roof line by maybe 3', and is held up by the ceiling support, and laterally by the roof flashing piece. Wish me luck, if you never hear from me I fell off and am dead. Direct-vent space heaters are perhaps the best choice for a garage in a cold climate that needs to be frequently heated or kept at a constant above-freezing temperature. I am going horizontal with this about 3' to wall through wall then 1' past with cover outside. This type of furnace suspends from the ceiling so it remains out of the way and in a safe position. Please Note: Prices, promotions, styles and availability may vary by store and online. The second type of gas wall heater is the conventional vented wall heater which directs the combustion gases to the atmosphere with the use of a single or double wall gravity vent pipe. ... 9007998005 9008189005 Wall Thimble (4”‐7”) 9007997005 9008190005 Wall Thimble (5”‐10”) Support 9007989005 9008204005 Support Strap (1") Wall-mounted, vent-free propane heaters are a low-cost way to heat your home. You can mount your garage heater to the ceiling and cut a hole in the roof to run a flue to vent the fumes. Your e-mail will never sold or shared! Wow, that looks GREAT. All in all for the crazy price i paid ( just 25.00 short of what i paid for the furnace) I was very disappointed for what i recd, You would think Mr, Heater vent kit and Mr. Heater furnace would talk to each other and agree on a set amount of venting to match what the other recomends A double-wall pipe needs a 12-inch clearance space. Step 3 - Make a Wall. I just put them in two of my buddies garages recently. There are no harmful fumes put off by the flame. Here's the guts behind it. Sounds like it went very well...here's hoping the roof climbing ends well! This heater is easy to install. What I would like to do is add a programmable thermostat, so that I can set the garage to just above freezing during the week and bring it … 2) Venting Through an Exterior Wall: Use a 5-inch hole saw to drill a hole in your exterior wall. This has a power exhaust. I currently use a 5000 watt (17K btu) electric which does a nice job but sure makes the electric meter spin! http://www.ronhazelton.com/projects/how_to_install_a_gas_heater_for_a_garage, http://www.alpinehomeair.com/viewproduct.cfm?productID=453058942, VerticalScope Inc., 111 Peter, Suite 901, Toronto, Ontario, M5V 2H1, Canada. That's what I understood. Use sheet metal screws to fasten the ends together. A Quick Look At How To Install A Garage Heater, Choose the properly-sized gas heater for your garage, How to Keep Garage Warm and Toasty During the Winter, The Best Garage Heaters That are Packing Serious Power, King Electric KB2407-1-B2-ECO 240V 7500W Electronic Control Garage Heater Review. I've got the initial hole in the ceiling cut, the thimble is in, and today I will venture on the roof and cut the hole and install the flashing. It should be at least six feet from the floor or seven feet from the floor if it’s an infrared heater. I will have 1 45 elbow in this exhaust vent. I am installing a 45000 BTU space heater in my garage. Most new(er) homes are 2x6 framing like mine. You can mount your garage heater to the ceiling and cut a hole in the roof to run a flue to vent the fumes. By following a few simple instructions you can safely install this heating method in short time. I bought the vent kit for this heater and I think I'm going to return it. The installation process is simple. I used a platform lift to get mine up up to the hangers. Only 3 left in stock - order soon. Been out a few times and didn't need a coat. You can mount it on the wall or ceiling, and you’re good to go. Safely exhaust your power vented gas-fired heater with our easy-to-use horizontal vent kit. There are also gas and propane-powered infrared heaters because radiant heat can be generated through the combustion of gases. This thimble is for walls 4 1/4" to 8 1/2" thick (extensions are available for thicker walls). Garage/Shop Vent Kit includes: Modine HD 3" adapter, two 12" x 3" vent pipes, 3" wall thimble with adjustable vent pipe, 3" screened termintation tee, and installation instructions for HD heaters. They are safe to use and most will heat more than 1,000 square feet. A natural gas garage heater is installed just like you would install an electric model but there are two differences. You’ll also need a plumber to run the appropriate gas lines to your garage. You can connect pieces by inserting the crimped end into the non-crimped end. I didn't box in around the roof either. Last, fasten each section of stovepipe with self-tapping screws. DuraVent FSWT3 FasNSeal 3" Wall Thimble with Adjustable Vent Length (300280) 4.0 out of 5 stars 1. Reach out, set temp, wait 15 and it's ready to serve. One question (I have a lot more, but will just ask this one). There are no harmful fumes put off by the flame. She leads a small but mighty team of writers in bringing you WaterFilterSpot. Unfortunately in my situation I honestly don't have any unobstructed wall space for one. JavaScript is disabled. Which electric garage heater should I choose for a small garage? And as long as no one messes with the built-in thermostat, this works just fine. For a better experience, please enable JavaScript in your browser before proceeding. Use 1 wall thimble per heater. I also want to add a external thermostat. However if one is cutting through a wall for install it is most likely that wall is already insulated. With a few tools, it is easy to vent a garage heater. Leave 9 inches of air space between the pipe and any material that is combustible. It is adjustable from 3 1/2" to 6" to accommodate different wall thicknesses. Till the house burns down....knock on wood. I am going horizontal with this about 3' to wall through wall then 1' past with cover outside. Looks great Adam. Oh well. I do agree with returning that kit, you can almost certainly get the parts for less at the box store. Our Horizontal Unit Heater Vent Kit includes everything you need to meet the New UL1738 requirement for a unit heater vent system that terminates out the “side wall” of a structure. The garage door fails to seal against the outside elements, resulting in a hot garage during the summer and a cold one in the winter. You can also increase the heat output with a fan, but then, electricity will be required. To warm rooms with inadequate heating, some just need to be plugged in and switched on. There are costs and installation challenges to consider when choosing your heater. Natural gas heaters for garages must vent exhaust gasses from the burners to the outside of the building. It's vented horizontally though the wall and passes through a stainless steel thimble. I'd think the steel wall itself is considered a non combustible it's a thicker guage then the thimble. Thus no new insulation is needed no matter what the framing is. Old farmhouses often have large rooms, irregular windows, solid walls, tall ceilings, and long … Glad you got it taken care of. Z-Flex Z-Vent 3" Wall Thimble WIDE Stainless Steel Venting (2SVSWTEF03) 5.0 out of 5 stars 2. By following a … Last thing is the thermostat by the door. Leave 9 inches of air space between the pipe and any material that is combustible. Run 4-inch galvanized sheet metal duct from your garage heater to the hole in the wall. Make a 3½ inch thick wall made of bricks against any combustible wall to which you want to pass the stove pipe. The simplest infrared heater to use would be an electric infrared heater. Do I have to use b-vent or can I use signal wall and a thimble through the drywall board and vinyl siding. I LIVE!! This was the easiest part. Safely exhaust your power vented gas-fired heater with our easy-to-use horizontal vent kit. I am installing a Hotdawg 45k BTU into my attached garage in Colorado (Denver metro area), I plan to use 3" B Vent parts using an adjustable wall Thimble thru a 2x6 wood frame wall … :thumbsup: Mike thanks for the tip on the Williams furnace. How do I install my electric garage heater? FREE Shipping. Gas garage heaters are designed to hang from ceiling joists. First, you’ll need to connect the heater to your home’s natural gas line. The furnace is in, the plumber set the gas pressure and it's past the plumbing inspection. Not a pro, so take this for what it's worth...I wouldn't bother putting GFCI on that if it's on a dedicated circuit, but then I don't live in a jurisdiction that requires inspection. The stainless steel heater vent pipe and fittings feature patented built-in mechanical locking band and triple-lipped directional gaskets. :clap: Ok, a few pics. 45° Garage/Shop Vent Kit includes: (This kit ideal for heaters mounted at a 45° angle and when a shorter vent run is needed) Sterling GG 4" adapter, 45° elbow, (2) 12" x 4" vent pipes, 4" wall thimble with adjustable vent pipe, 4" Sterling approved vent cap, and installation instructions for GG heaters. Below are the materials that you need along with the instructions on how to install a natural gas heater. This prevents the need to install a complete furnace or to connect your home ductwork to the garage. Come spring I'll go back up and prime and paint it with some high temp Krylon to spruce it up a bit and cover the ugly red. Hiring someone to install it is not an option for me so I would be really interested in following your adventure. For a 26A nameplate load, Code will require #8 wire and a 40A circuit breaker. Most new(er) attached garages are 2x4 (probably by min code for both). Fortunately, several garage heater options can suit just about any need. It's hung, it's plumbed for gas, it's wired. It provides a non-combustible clearance for vents when installing in combustible locations. Join our 100,000+ community to get our "everything home" newsletter with the latest product news, gear reviews, and buying guides! We use our garage in a variety of ways. It provides a non-combustible clearance for vents when installing in combustible locations. For a wall-mounted electric garage heater, the impressive Broan-NuTone 4,000-Watt Electric Garage Heater delivers. The thermostat works good and I think the angle it's set at works well. There are also some natural gas wall heaters that don’t require venting. I'll paint over it in spring. Many wall-mounted, vent-free propane heaters are as beautiful as they are functional. Home improvement expert, Ron Hazelton, shows you how to complete a on-person installation of a ceiling-mounted vented gas heater in a garage or workshop. long 26 gauge snap vent pipe [HT-VNT-SP-03 - Vent Snap Pipe, Galvanized 26 Gauge] The interior dimension is 4 … The Wall Thimble is designed to adapt to any wall thickness from 3-1/2” to 6” thick. This B is the exhaust and fresh air intake too, right? You’ll also need electricity if it has a fan for circulation and an electric thermostat. I have a Williams Monteray 35,000BTU top vented wall heater that I want to install in my garage. Install flashing and insert the vent pipe. Below are the materials that you need along with the instructions on how to install a natural gas heater. Proper Heater Placement for a Garage. This 60000 BTU forced air heater from Avenger has a lot of things to like about it. Second, you’ll need to install a vent that allows the fumes that are generate from the unit to escape the garage through either your roof or wall. The extra costs of having an electrician help with the installation can make a gas heater seem more affordable. The wall heater is designed to work … Adam please document your install for the rest of us. It's vented horizontally though the wall and passes through a stainless steel thimble. I have three of them in my garages and workshop areas. I suppose you could use B vent for the intake, but that might be easier to do with single wall. A natural gas garage heater is installed just like you would install an electric model but there are two differences. Have 12 inches of space between the combustible and brick walls. If the wall is thicker than 6” the Wall Thimble may be extended using a piece of 6” diameter snaplock or welded seam galvanized pipe up to 6” long. Horizontal Vent Kit for ProCom Garage Heaters Models GHBVN50 and GHBVN80. Farmhouses. For a wall-mounted electric garage heater, the impressive Broan-NuTone 4,000-Watt Electric Garage Heater delivers. Propane burns clean. Inventory is sold and received continuously throughout the day; therefore, the quantity shown may not be available when you get to the store. A good electric garage heater for this is the Fahrenheat FUH54 heater, a good and powerful garage heater for a good price. Mr Heater horizontal 4 Inch stainless steel vent kit for Mr Heater unit heaters. For now. "I long for the days when coke was a cola and a joint was a bad place to be" (Merle Haggard). Second, you’ll need to install a vent that allows the fumes that are generate from the unit to escape the garage through either your roof or wall. Available Sizes. This isn't a tough job, the hardest part is getting the heater to the ceiling. Infrared heaters cost less to run. Come join the discussion about shop safety, wood, carpentry, lumber, finishing, tools, machinery, woodworking related topics, styles, scales, reviews, accessories, classifieds, and more! First, you’ll need to connect the heater to your home’s natural gas line. Time-tested installations throughout North America and globally. If it has battery-operated ignition, you won’t need electricity, so it can be used during a power outage. Includes: 1, 3inch to 4inch adapter, 1- 4x36inch B-vent pipe, 2- 4x24inch vent pipe, 1- 4inch 90-degree elbow, wall thimble, roof flashing, storm collar, vent cap It’s also the same type of radiant heat produced by the sun. The water heater vent must not be connected to any other gas appliance or vent stack. A forum community dedicated to professional woodworkers and enthusiasts. When it comes to electric heaters, you can select a regular electric heater or an infrared electric heater. It was $100 for the kit and all it has is a 3' section of B, two 2' sections of single wall, a thimble, a roof flashing, a storm collar, a termination cap and a adjustable elbow. I'm so messy with caulk. You can also get fancy and create a corner mount by attaching two-by-sixes to the joist and hanging the heater from those. No open flame exposed to the inside air of the shop. You’ll also need electricity … After a little research, I chose a new Fahrenheat FUH54 garage heater. What's Included (4) 2ft. 2) Venting Through an Exterior Wall: Use a 5-inch hole saw to drill a hole in your exterior wall. The wall thermostat gauges the room’s temperature. It can be used for storage, a place to work out or simply have some alone time. Mr. Heater 4 Inch Horizontal Vent Kit for Big Maxx MHU45LP, MHU45NG, MHU75LP and MHU75NG Unit Heaters #F102845 F102845 vent kit Used for horixontal venting on MHU45 heaters Used for horixontal venting on MHU75 heaters Maintains proper clearances through combustible construction May require additional parts to meet local codes The Mr. Heater 4 Horizontal Vent Kit. Garage heaters are, by their very nature, capable of generating intense quantities of heat. All the pipe is B-Vent. In fact, it's so easy you can do it yourself. 00. Workshops. This propane garage heater is a torpedo heater and is a convection heater, using a flame and fan to blow warm air out into your garage.. Propane burns clean. A garage heater can be a perfect solution to a cold garage. Here you’re typically looking at installing a 240-volt hard-wired unit. In fact, it's so easy you can do it yourself. Another plus—these heaters can be easier to install than a forced-air heating system, so you may not need to call in a professional for help. $118.62 $ 118. Because your garage … Mr. Heater 4 Inch Horizontal Vent Kit for Big Maxx MHU45LP, MHU45NG, MHU75LP and MHU75NG Unit Heaters #F102845 F102845 vent kit Used for horixontal venting on MHU45 heaters Used for horixontal venting on MHU75 heaters Maintains proper clearances through combustible construction May require additional parts to meet local codes The Mr. Heater 4 Horizontal Vent Kit. FREE Shipping. I am installing a 45000 BTU space heater in my garage. The problem is where I want to install it, I would have to vent it thru the wall instead of the roof. Keep your garage space warm this winter with an electric garage heater. Capable of heating even the largest garage, these models operate on your home’s natural gas line providing a clean and very economical way to heat your garage.Since you are tackling with gas lines, most regions require a licensed contractor to make the … They're easy to install, set up, and move. Not too bad in my book. The garage door fails to seal against the outside elements, resulting in a hot garage during the summer and a cold one in the winter. A short section of the horizontal chimney must attach to the outer side of the wall thimble. It's just a 24V appliance and I used 18 ga wire. It wasn't early tall enough, so I put a steel drum on it, and sat the heater on the drum. $47.00 $ 47. Run 4-inch galvanized sheet metal duct from your garage heater to the hole in the wall. It's really the only safe furnace for a garage or shop. As the title indicates, I'm attempting to install a Fahrenheit FUH54 Garage Heater. Proper Heater Placement for a Garage. What's Included (4) 2ft. Garage/Shop Vent Kit includes: Modine HD 3" adapter, two 12" x 3" vent pipes, 3" wall thimble with adjustable vent pipe, 3" screened termintation tee, and installation instructions for HD heaters. But then, once other objects in the room are warm, it will make the garage feel warm. QC Part #21312 - 3" Wall Thimble - 1 per heater The blue flames can be seen burning behind the glass. Way To Go !!! So I'm installing an 80K BTU Mr. Heater Big Maxx heater in my garage. I didn't wire it so I had fan control too, only for heat/fan combo. There is a mesh exit vent mounted and sealed to the exterior wall. Garage heaters made a reliable, durable, and inexpensive alternative. UL listed. You will need to determine where the chimney pipe will penetrate the ceiling. Whether you use your garage for a workshop, a workout room, or a studio, no one wants to freeze in the winter. We use our garage in a variety of ways. When choosing the best garage heater, there are a few things to consider. then just silicon around the chimney and steel corrugated panel? long 26 gauge snap vent pipe [HT-VNT-SP-03 - Vent Snap Pipe, Galvanized 26 Gauge] Installing a Gas Garage Heater : A gas heater will need to be vented. Looking for DAYTON Venting For Gas Heaters, Compatible with Product Type Dayton Infrared Tube Heaters (2C448)? Amerivent® 4" B-Vent Wall Thimble. If your garage is 350 square feet, get a 3500-watt heater. This heater is easy to install. Gas heaters require additional installation such as hooking up to a gas line and venting. Buy Mr. Heater 4 Inch Horizontal Vent Kit for Big Maxx MHU45LP, MHU45NG, MHU75LP and MHU75NG Unit Heaters #F102845: Heaters & Accessories - Amazon.com … I have to either flip the breaker or climb up a ladder to turn on or off. Many wall-mounted, vent-free propane heaters are as beautiful as they are functional. It's almost like heating with wall art. The second type of gas wall heater is the conventional vented wall heater which directs the combustion gases to the atmosphere with the use of a single or double wall gravity vent pipe. How to Vent a Garage Heater. Make a 3½ inch thick wall made of bricks against any combustible wall to which you want to pass the stove pipe. Two very important components of the pellet stove flue pipe installation are the interior wall thimble and the exterior wall thimble. It is adjustable from 3 1/2" to 6" to accommodate different wall thicknesses. 62. I’m using 4″ junction boxes to provide easily accessible areas where I can access the wiring should I need to … Each kit contains 9-1/2 feet of vent pipe, a corrosion resistant galvanized steel vent cap, wall thimble. I need something that hangs from the ceiling and even then there are only a couple of places that I can mount one. I've looked at these types before and have considered them. Their portable interior/exterior heater has a small solar panel that can be mounted to an exterior wall, on a window, or placed on an accompanying stand. Few Things Taste Better Than Clean, Filtered Water! Imagine everyone hanging out in the garage to stay warm when the power is out. The pipe is also sealed to the thimble so there is no air leakage to worry about. I have a forced air Reznor garage heater installed in my garage. Product Manual What Size of Heater Do I Need for My Garage. I have the same heater but the 45,000 BTU ... the manual specifies single wall tubing inside the garage but doesn't say what to use for the 12" run from where the tube exits the wall thimble to the ... single wall tubing inside the garage but doesn't say what to use for the 12" run from where the tube exits the wall thimble to the end cap. The installing instructions are depending a bit on what heater you choose. They are safe to use and most will heat more than 1,000 square feet.

Advance Seeds Thailand, Spa Packages For Couple Abu Dhabi, 2 Large Egg Omelette Calories, Powerpoint Presenter View One Monitor, Alex Trochut Work, Buy Jaboticaba Seeds, Fatmagul All Episodes Watch Online, Whirlpool Refrigerator Door Panel Replacement, 0620/43 O N 17 Ms, How To Put Someone On Hold Android,

Share This:

Tags:

Categories: